Eperfás Tanya Mórahalom

INDIRECT STORAGE TANKS

Type
OKC 300 NTR
OKC 400 NTR
OKC 500 NTR
Tank Capacity
L
300
390
435
Diameter
mm
701.5
701.5
701.5
Weight
kg
120
145
175
The hot water working pressure
MPa
A
A
A
The heating water working pressure
MPa
A
A
A
The heating up of water. pressure
° C
110
110
110
The hot water temperature
° C
95
95
95
The heat exchanger heating surface
2 m
1:45
1.8
1.9
The heat exchanger performance
kW
48
57
65
Performance Evaluation of DIN 4708
NL
8.4
2.15
1.19
The indirect permanent storage capacity *
l / h
1180
1395
1590
Heat loss during the 24h
kWh
1.68
2
2.3
* The hot water at 45 ° C
OKC 300 NTR
OKC 400 NTR
OKC 500 NTR
The
1294
1591
1921
B
1226
1523
1853
C
918
1111
1264
D1
597
597
597
D2
701.5
701.5
701.5
E
720
909
965
F
547.5
684
695
G
755
957
1040
Type
OKC 300 NTR
OKC 400 NTR
OKC 500 NTR
Tank Capacity
L
292
380
472
Diameter
mm
600
701.5
701.5
Weight
kg
130
185
215
The hot water working pressure
MPa
A
A
A
The heating water working pressure
MPa
A
A
A
The heating up of water. pressure
° C
110
110
110
The hot water temperature
° C
95
95
95
The upper surface of heat exchanger
2 m
0.8
1:05
1.2
The lower heat exchanger heating surface
2 m
1:55
1.8
1.5
The lower / upper exchanger
kW
45/27
51/31
58/40
Performance Evaluation of the upper heat exchanger according to DIN 4708
NL
2.5
5.7
8.5
Performance Evaluation of the lower heat exchanger according to DIN 4708
NL
4.1
9.4
7.14
The indirect permanent storage capacity of the lower heat exchanger *
l / h
1170
1250
1566
The indirect permanent storage capacity of the upper heat exchanger *
l / h
630
740
960
Heat loss during the 24h
kWh
1.68
2
2.2
* The hot water at 45 ° C
5 year warranty on inner tank and 12 months for electric parts
OKC 300 NTR
OKC 400 NTR
OKC 500 NTR
The
1794
1591
1921
B
1014
957
1040
C
324
275
275
D1
500
597
597
D2
600
701.5
701.5
E
1725
1523
1853
F
1424
1354
1604
G
1289
1223
1409
Mon
1179
1111
1264
I
1064
1006
1114
J
964
909
965
Tues
403
369
380
L
254
220
220
M
90
55
55
N
38
25
25
Indirect connection to the storage of two pumps, connected to plumbing system, heating and domestic hot water system
First Indirect storage
8th Heat Detector
Second Indirect heat exchanger storage
9th Check valve
Third Expansion tank
10th Thermometer
4th Pump
11th Motorized mixing valve
5th Snubber
12th Drain valve
6th Pressure gauge
13th Author valve
7th Safety valve
14th The indirect container drain valve
The connection indirekttároló way to hot water and heating systems using three-way valve:
First Indirect storage
8th Heat Detector
Second Indirect heat exchanger storage
9th Check valve
Third Expansion tank
10th Thermometer
4th Pump
11th Motorized mixing valve
5th Snubber
12th Drain valve
6th Pressure gauge
13th Author valve
7th Safety valve
14th The indirect container drain valve
15th Three-way valve